Getting your requirements straight

When you are about to build a RAID, make sure you understand your storage requirements. The following points are significant:

The RAID triangle

The relationship between Speed, Price, and Fault Tolerance mostly determines the RAID level to use. Of these three parameters, pick any two and you are all set.

It may seem that RAID 5 and RAID 6 are expensive, but as the capacity of the array and the number of disks increase, the overhead of the RAID 1+0, both in disks and in controller ports, becomes significant.

Do you really need RAID 0?

If you are planning to build a RAID 0, consider using an SSD instead. Depending on what your requirements are, you may find a better bang for your buck with just one SSD. Also, higher RPM rotational drives (e.g. WD VelociRaptor series) or hybrid drives (like Seagate Momentus XT) may be interesting, depending on your particular usage patterns.

As the capacity requirements increase, two things happen:

So for a large capacity storage a RAID 0 or even RAID 10 array would be cheaper and can still meet the performance requirements for most any practical application. If you do not need large capacity, consider a single SSD instead of a RAID 0 or two SSDs in RAID 1 instead of RAID 10. Also, because RAID does not improve minimum access time, an SSD is by far the best choice for heavy random access.

RAID 5 vs. RAID 6

If you plan on building RAID 5 with a total capacity of more than 10 TB, consider RAID 6 instead.

The problem with RAID 5 is that once a member disk has failed, one more failure would be irrecoverable. To reduce the probability of double failure you need to monitor the array and/or use hot spares. However, even if the RAID rebuild is commenced immediately once the drive fails, it is required to read the entire array in order to complete the rebuild. Although the probability of encountering a read error in any particular read operation is very low, the chance of a read error occurring increases with the array size. It has been widely speculated that the probability of encountering a read error during the rebuild becomes practically significant as the array size approaches 10TB. Although the speculation relies on certain assumptions which are not likely true (refer to the bonus section for details), having to restore from the backup is not pleasant. By the way you do have backups, do you?

RAID 6, being capable of correcting two simultaneous read errors, does not have this problem.

Hot spares

Hot spares are a good addition to a fault-tolerant array. They greatly reduce the impact of monitoring on the array reliability.

If a drive has failed in a fault-tolerant (RAID 1, RAID 10, RAID 5, or RAID 6) array, a vulnerability window opens. If another drive fails during this vulnerability window, the data is lost. Without the hot spare, the rebuild does not commence until someone walks in and physically replaces the failed drive. Hot spare drives allow the controller to commence the rebuild immediately, without having to wait for administrator intervention, thereby reducing the vulnerability window.

The need for a hot spare increases as the number of disks in array increases.

Hot spares are most effective when a single hot spare drive is shared between several arrays. Consider for example an 8-bay NAS. If there is only one RAID 5 array in the NAS, then RAID 6 may be a better option than a hot spare. The hot spare drive just sits there idly; in a RAID 6 array, the same drive would be utilized to improve a read speed. However if you need two RAID 5 arrays, the hot spare drive is shared between these two arrays, reducing the total disk space overhead.

Software RAID is not dead

Do not underestimate a software RAID.

The significant side effect is that you cannot reliably boot from a software RAID.

Test your RAID

The fault tolerance needs to be tested so that you:

When deploying a fault-tolerant array (RAID 1, RAID 10, RAID 5, or RAID 6), test the system with a simulated disk failure.

You need to verify that the system behaves precisely as expected in all aspects. This obviously includes that the array is still accessible. Less obvious, but nonetheless required is to verify that all the notifications were sent and received properly: emails, SMS, and possibly pre-recorded phone calls. Also, check your ability to identify the failed drive easily. Either the appropriate drive bay light should turn red, or the array diagnostic software should give you a clear number of a failed drive bay.

While you are at it, do a simulated power failure by pulling the UPS plug out of its socket. The system should remain online for some predefined period and then gracefully shut down. Ensure that the UPS battery is not fully depleted by the time the shutdown completes.

Obviously, you better do the testing before the array is loaded with the production data, or might have an unplanned RAID recovery incident.

Prevention I - Backup often

Even if your RAID is supposed to be fault tolerant, backup often. Neglecting the backup is by far the worst and the most common mistake people make. They think like "Hey, we got RAID, it is fault-tolerant, made by the best vendor out there, cost us like a small car, so it must be reliable. We do not need backup anymore".

Although the RAID is redundant with respect to hard drive failures, there are still issues that may bring down the entire array, requiring either a restore from a backup or a RAID recovery.

Prevention II - Monitor RAID performance

The ability of the RAID to handle failures of its hard drives relies on two things:

  1. Built-in redundancy of the storage. The RAID has some extra space in it, and the end-user capacity of a fault-tolerant array is always less than the combined capacity of its member disks.
  2. Diligence of people to provide additional redundant storage should the built-in reserve fail.

Once redundancy is lost because of the first drive failure, the human intervention is needed to correct the problem and restore the required level of redundancy. Redundancy is to be restored quickly, or otherwise there is no point in having the RAID at all.

However, you do not know when to act if you do not monitor the array and the disks often enough.

Recover RAID

If a disk fails in a fault-tolerant array such as RAID 5, you just replace the disk and carry on. A fault-tolerant array is just that - designed to provide fault tolerance. However, if there is a controller failure or an operator error, you might end up with a set of disks lacking the array configuration. The set of disks may be either complete (including all the member disks) or incomplete (missing a disk or several disks). While not having a complete disk set slows down the possible recovery, losing one disk is not necessarily irreversible.

You can then send the disk set to the data recovery lab, or try to get the data off yourself using ReclaiMe Free RAID Recovery. Whatever you do, if at all practical you should make disk image files (sector-by-sector copies) of the array member disks. These image files act as an additional safety layer if one more member disk dies while you're busy recovering. Remember to make images of separate member disks, not the entire array.

The most difficult part of RAID recovery is the destriping, the process of converting the striped array to the contiguous set of sectors as it is on a regular hard drive. ReclaiMe Free RAID Recovery does exactly that, giving you a choice of several output options, and at no cost. You can even make it interact with certain third-party data recovery tools, providing necessary preprocessing to make them capable of handling the RAID.

Bonus Fear, Uncertainity, and Doubt - Unrecoverable errors in RAID 5 revisited

There is a known and widely discussed issue with RAID 5. If one drive in the array fails completely, then during the rebuild there may be a data loss if one of the remaining drives encounters an unrecoverable read error (URE). These errors are relatively rare, but sheer size of modern arrays leads to speculation that one cannot even read the entire array reliably (without encountering a read error).

There are some pretty scary calculations available on the Internet. Some are concluding that there is as much as 50% probability of failing the rebuild on the 12TB (6x2TB) RAID 5.

The calculation goes like this: let's say we have a probability p of not being able to read the bit off the drive. Then, q = 1 - p is the probability of the successful read, per bit. To be able to rebuild the RAID 5 array of N disks C terabytes each, one needs to read C*(N-1) terabytes of data. Let's denote the number of bits to read as b = C * (N-1) * 8 * 1012 and we arrive at the probability of successfully completing the rebuild P = qb.

The value of p is provided in the hard drive specification sheet, typically around 1015 errors per bit read.

Specified URE
1014
1015
1016

Probability of rebuild failure for 6x 2TB drives
~55%
~10%
~0%

These calculations are based on somewhat naive assumptions, making the problem look worse than it actually is. The silent assumptions behind these calculations are that:

Both of these are not true, making the result useless. Moreover, the whole concept of specifying a bit-level stream-based error rate for a block-based device which cannot read less than 512 bytes of data per transaction seems doubtful.

The original statement can be transformed into something more practical:

The statement "There is a 50% probability of being not able to rebuild a 12TB RAID 5" is the same as "If you have a 10TB RAID 0 array, there is a 50% probability of not getting back what you write to it, even if you write the data and then read it back immediately." That's assuming the same amount of user data on both arrays and 2TB hard drives. Still, nobody declares RAID 0 dead.

This can be reformulated even further: assuming 100MB/sec sustained read speed, we can say "There is a 50% chance that a hard drive cannot sustain a continuous sequential read operation for 30 hours non-stop", which just does not look right. 30 hours is the approximate time to read 10TB of data at 100MB/sec.

Bonus Modern Marvels – BTRFS, ZFS, Microsoft Storage Spaces

As of late, there is some drift to create hybrid solutions combining filesystem and RAID into a single module, or a single storage layer, whichever way you call it. If you have a choice between one of this hybrid filesystems and a traditional RAID controller, go with the traditional RAID whenever possible.

This includes (but is obviously not limited to)

Заключение

От себя добавлю следующее